Changes for page UC03.2: Wide area assessment (USAR)
Last modified by Tjalling Haije on 2025/09/15 09:25
From version 4.1
edited by Rosa Van Tuijn
on 2025/07/09 07:45
on 2025/07/09 07:45
Change comment:
There is no comment for this version
To version 2.2
edited by Tjalling Haije
on 2025/07/07 11:00
on 2025/07/07 11:00
Change comment:
Update document after refactoring.
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -UC0 3.2:Wideareaassessment(USAR)1 +UC01.2: Health sensors (USAR) - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -2\. Specification.b\. Use Cases.UC0 3\.0\:Wideareaassessment.WebHome1 +2\. Specification.b\. Use Cases.UC01\.0\: Health Sensors.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. RosaVanTuijn1 +XWiki.TjallingHaije - Content
-
... ... @@ -1,11 +1,11 @@ 1 -=== ** Wideareaassessment– USAR** ===1 +=== **Health Sensor – USAR** === 2 2 3 -|=**Objective**|= 4 -|**TDP**| 5 -|**IDP**| 6 -|**Actors**| 7 -|**Pre-Condition**| 8 -|**Post-Condition**| 3 +|=**Objective**|=Use health sensors to monitor USAR responders during operations, enabling real-time intervention and mission adjustment. 4 +|**TDP**|TDP3, TDP6, TDP7 5 +|**IDP**|IDP2, IDP4 6 +|**Actors**|Responder, Team Leader, Medical Staff, Safety Officer 7 +|**Pre-Condition**|Wearables calibrated and worn before entering the operational zone. 8 +|**Post-Condition**|Health data processed; alerts triggered; medical decisions informed. 9 9 10 10 11 11 ... ... @@ -13,8 +13,32 @@ 13 13 14 14 === **Action Sequence** === 15 15 16 +1. **Sensor Setup and Readiness** 17 + a. Wearables are distributed and calibrated at staging area. 18 + b. Each responder confirms correct placement and pairing. 19 + c. System diagnostics confirm connectivity to C3I and health monitoring software. 20 +1. **Monitoring and Local Alerts** 21 + a. Wearables measure vitals (e.g. heart rate, temp, hydration). 22 + b. Local LED/sound alerts notify responder of rising stress or danger. 23 + c. Non-critical data is logged passively for review. 24 +1. **Remote Monitoring and Escalation** 25 + a. Safety officer observes all live health feeds via dashboard. 26 + b. Alerts for critical thresholds trigger visual/audio warnings. 27 + c. Team leader is notified and confirms next action (pause, replace, extract). 28 +1. **Medical Decision and Evacuation** 29 + a. Medic evaluates responder if thresholds persist. 30 + b. If required, team extracts responder for treatment. 31 + c. Info logged and synced to medical HQ for continuity of care. 32 +1. **Command-Level Operational Adjustment** 33 + a. Based on patterns, team rotations or routes are adjusted. 34 + b. System records trends for debrief and post-mission reporting. 35 + 16 16 ---- 17 17 18 18 |=**Claims (title)**|=**Function**|=**Effect(s)**|=**Action Sequence Step(s)** 39 +|CL1 Heightened safety in worksite|Vital monitoring, Local alerts|Reduces risks due to unnoticed physical strain|2a, 2b, 3a 40 +|CL2 SA of own status|LED/sound feedback|Empowers self-correction or request for help|2b 41 +|CL3 SA for managers|Live health dashboard|Enables proactive responder care|3a, 3b 42 +|CL4 Better decisions using status data|C3I health data, Escalation protocol|Supports informed team rotation and extraction|4a, 4b, 5a 19 19 20 20