Version 16.1 by Mark Rinse van Koningsveld on 2025/07/14 11:11

Show last authors
1 === **Health and environmental monitoring – Firefighting** ===
2
3 |=**Objective**|=(((
4 [[OB03: Improve first responder health through monitoring of physical and mental state >>2\. Specification.Objectives.OB03\: Improve health through monitoring of physical and mental state .WebHome]]
5
6 [[OB04: Improve safety by providing overviews and warnings of environment conditions>>2\. Specification.Objectives.OB04\: Improve safety by providing overviews and warnings of environment conditions.WebHome]]
7 )))
8 |**TDP**|TDP3, TDP6, TDP7
9 |**IDP**|IDP2, IDP4
10 |**Actors**|Firefighter, Squad Leader, Medic, Safety Officer
11 |**Pre-Condition**|Wearables are active and connected before firefighters enter the danger zone.
12 |**Post-Condition**|Health alerts handled; intervention performed if needed.
13
14
15
16 ----
17
18 (% style="margin: 15pt 0cm 7.5pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;" %)
19 === (% style="font-weight:normal" %)**Action Sequence**(%%) ===
20
21 (((
22
23 )))
24
25 === ===
26
27 (% start="1" style="list-style-type:decimal" type="1" %)
28 1. (% lang="EN-US" style="font-size:10.5pt" %)**Equipment Check and Deployment**(%%)
29 (% style="font-size:10.5pt" %) (% lang="EN-US" %)a. Firefighters quickly put on wearable sensors when mission is confirmed(%%)
30 (% style="font-size:10.5pt" %) (% lang="EN-US" %)b. Safety officer confirms connectivity before entry.(%%)(((
31
32 )))
33 1. (% lang="EN-US" style="font-size:10.5pt" %)**Live Monitoring in Action**(%%)
34 (% style="font-size:10.5pt" %) (% lang="EN-US" %)a. Vitals (e.g. heart rate, CO exposure) are tracked during fire suppression.(%%)
35 (% style="font-size:10.5pt" %) (% lang="EN-US" %)b. Firefighters receive vibration or LED warnings if thresholds exceeded, but can turn these off when needed(%%)
36 (% style="font-size:10.5pt" %) (% lang="EN-US" %)c. Alerts escalate automatically for predefined danger levels.(%%)(((
37
38 )))
39 1. (% lang="EN-US" style="font-size:10.5pt" %)**Remote Oversight and Alerts**(%%)
40 (% style="font-size:10.5pt" %) (% lang="EN-US" %)a. Safety officer monitors dashboard for all team vitals with simple colour indicators(%%)
41 (% style="font-size:10.5pt" %) (% lang="EN-US" %)b. Critical alerts are sent to squad leader.(%%)
42 (% style="font-size:10.5pt" %) (% lang="EN-US" %)c. Local health services prepare for immediate support if triggered. In case of a false alarm squad lead is able to cancel it.(%%)(((
43
44 )))
45 1. (% lang="EN-US" style="font-size:10.5pt" %)**Intervention and Team Adjustment**(%%)
46 (% style="font-size:10.5pt" %) (% lang="EN-US" %)a. Firefighter is pulled out if condition worsens.(%%)
47 (% style="font-size:10.5pt" %) (% lang="EN-US" %)b. Medic assesses and logs health data.(%%)
48 (% style="font-size:10.5pt" %) (% lang="EN-US" %)c. Squad leader adjusts team composition or rest timing.(%%)(((
49
50 )))
51 1. (% lang="EN-US" style="font-size:10.5pt" %)**Post-Incident Reporting**(%%)
52 (% style="font-size:10.5pt" %) (% lang="EN-US" %)a. System logs are exported for incident review.(%%)
53 (% style="font-size:10.5pt" %) b. Health data supports tactical evaluation and accountability.(%%)(((
54
55 )))
56
57 ----
58
59 |=**Claims (title)**|=**Function**|=**Effect(s)**|=**Action Sequence Step(s)**
60 |**CL1 Decreased physical workload for responders**|Health tracking, wearable alert|(((
61 Reduces physical workload by alerting and preventing overexertion → Measure with ??
62 )))|2a, 2b, 2c, 3a
63 |(((
64 **CL2 Improve safety for responders **
65
66
67 (gedrag (SA) > houden afstand van hazard (e.g. gas))
68 )))|Monitoring and alerting of toxic gasses
69 **Note**: is this an envisioned functionality?|(((
70 Improves safety by reducing (toxic) gas exposure
71 → Measure with FR time near toxic gasses, or with near incident analysis.
72 )))|2a, 2b, 2c, 3a
73 |(((
74 **CL4 Improve safety of responders for the commander**
75
76
77 )))|Safety officer monitors team vitals|(((
78 Safety officer improves safety of FR by double checking FR status → measured as above
79 )))|3a, 3b
80 |**CL5 Decrease physical workload for responders**|Safety officer monitors team vitals|Safety officer decreases physical workload by double checking FR status → measured as above|
81 |**CL6 Improved SA on personnel status for team lead (and command)**|Alert escalation, Live dashboard, Auto-alerts|Command has improved SA on health status of personnel
82 → Measure with NASA TLX ?|3a, 3b
83 |**CL7 Support continuous learning with health data for after action review**|Health data over time of all FR is exported (and replayable?) after mission|Lessons learned can be idenitified and incorporated incorporated effectively
84 → measure with ?? |5a, 5b
85 |**CL8 Task performance increased**|All of the other functions|Task is completed quicker and with better results due to more efficient use of personnel
86 → Measure with time to mission completion and quality?|all steps