Changes for page UC01.1: Health and environmental monitoring (Firefighters)
Last modified by Tjalling Haije on 2025/09/15 09:25
From version 3.1
edited by Tjalling Haije
on 2025/07/07 11:20
on 2025/07/07 11:20
Change comment:
There is no comment for this version
To version 5.1
edited by Tjalling Haije
on 2025/07/08 08:46
on 2025/07/08 08:46
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -40,9 +40,30 @@ 40 40 ---- 41 41 42 42 |=**Claims (title)**|=**Function**|=**Effect(s)**|=**Action Sequence Step(s)** 43 -|CL1 Heightened safety for responders|Health tracking, Alert escalation|Prevents unnoticed overexertion or gas exposure|2a, 2c, 3a 44 -|CL2 SA for own condition|Wearable alerts|Responders recognize and act on stress|2b 45 -|CL3 SA for command|Live dashboard, Auto-alerts|Command can intervene based on data|3a, 3b 46 -|CL4 Operational effectiveness|Medical input, Tactical decisions|Supports better crew deployment and rotation|4c, 5b 43 +|CL1 Decreased physical workload for responders|Health tracking, wearable alert|((( 44 +Reduces physical workload by alerting and preventing overexertion ~-~-> Measure with ?? 47 47 46 +(Oude effect van Mark: Prevents unnoticed overexertion ) 47 +)))|2a, 2b, 2c, 3a 48 +|CLX Improve safety for responders|Monitoring and alerting of toxic gasses 49 +**Note**: is this an envisioned functionality?|((( 50 +Improves safety by reducing (toxic) gas exposure ~-~-> Measure with FR time near toxic gasses, or with near incident analysis. 51 + 52 +(prevents gas exposure) 53 +)))|2a, 2b, 2c, 3a 54 +|((( 55 +CLX Improve safety of responders 56 + 57 +CLX Decrease physical workload for responders 58 +)))|Safety officer monitors team vitals|((( 59 +Safety officer: 60 + 61 +* improves safety of FR by double checking FR status ~-~-> measured as above 62 +* Decreases physical workload by double checking FR status ~-~-> measures as above 63 +)))|3a, 3b 64 +|CL3 Improved SA on personnel status for team lead (and command)|Alert escalation, Live dashboard, Auto-alerts|Command has improved SA on health status of personnel ~-~-> Measure with NASA TLX (?)|3a, 3b 65 +|CLX Support continuous learning with health data for after action review|Health data over time of all FR is exported (and replayable?) after mission|Lessons learned can be idenitified and incorporated incorporated effectively ~-~-> measure with ?? |5a, 5b 66 +|CL4 Task performance increased|All of the other functions|Task is completed quicker and with better results due to more efficient use of personnel ~-~-> Measure with time to mission completion and quality (?) 67 +**Note: **this claim spans the entire usecase. How do we deal with those types of claims? |all steps 68 + 48 48