Last modified by Tjalling Haije on 2025/09/15 09:25

From version 2.2
edited by Tjalling Haije
on 2025/07/07 11:00
Change comment: Update document after refactoring.
To version 5.1
edited by Tjalling Haije
on 2025/07/08 08:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,10 @@
1 1  === **Health Sensor – Firefighting** ===
2 2  
3 -|=**Objective**|=Use health sensors to monitor firefighter vitals during operations, improving responder safety and enabling command decisions.
3 +|=**Objective**|=(((
4 +[[OB03: Improve first responder health through monitoring of physical and mental state >>2\. Specification.Objectives.OB03\: Improve health through monitoring of physical and mental state .WebHome]]
5 +
6 +[[OB04: Improve safety by providing overviews and warnings of environment conditions>>2\. Specification.Objectives.OB04\: Improve safety by providing overviews and warnings of environment conditions.WebHome]]
7 +)))
4 4  |**TDP**|TDP3, TDP6, TDP7
5 5  |**IDP**|IDP2, IDP4
6 6  |**Actors**|Firefighter, Squad Leader, Medic, Safety Officer
... ... @@ -36,9 +36,30 @@
36 36  ----
37 37  
38 38  |=**Claims (title)**|=**Function**|=**Effect(s)**|=**Action Sequence Step(s)**
39 -|CL1 Heightened safety for responders|Health tracking, Alert escalation|Prevents unnoticed overexertion or gas exposure|2a, 2c, 3a
40 -|CL2 SA for own condition|Wearable alerts|Responders recognize and act on stress|2b
41 -|CL3 SA for command|Live dashboard, Auto-alerts|Command can intervene based on data|3a, 3b
42 -|CL4 Operational effectiveness|Medical input, Tactical decisions|Supports better crew deployment and rotation|4c, 5b
43 +|CL1 Decreased physical workload for responders|Health tracking, wearable alert|(((
44 +Reduces physical workload by alerting and preventing overexertion ~-~-> Measure with ??
43 43  
46 +(Oude effect van Mark: Prevents unnoticed overexertion )
47 +)))|2a, 2b, 2c, 3a
48 +|CLX Improve safety for responders|Monitoring and alerting of toxic gasses
49 +**Note**: is this an envisioned functionality?|(((
50 +Improves safety by reducing (toxic) gas exposure ~-~-> Measure with FR time near toxic gasses, or with near incident analysis.
51 +
52 +(prevents gas exposure)
53 +)))|2a, 2b, 2c, 3a
54 +|(((
55 +CLX Improve safety of responders
56 +
57 +CLX Decrease physical workload for responders
58 +)))|Safety officer monitors team vitals|(((
59 +Safety officer:
60 +
61 +* improves safety of FR by double checking FR status ~-~-> measured as above
62 +* Decreases physical workload by double checking FR status ~-~-> measures as above
63 +)))|3a, 3b
64 +|CL3 Improved SA on personnel status for team lead (and command)|Alert escalation, Live dashboard, Auto-alerts|Command has improved SA on health status of personnel ~-~-> Measure with NASA TLX (?)|3a, 3b
65 +|CLX Support continuous learning with health data for after action review|Health data over time of all FR is exported (and replayable?) after mission|Lessons learned can be idenitified and incorporated incorporated effectively ~-~-> measure with ?? |5a, 5b
66 +|CL4 Task performance increased|All of the other functions|Task is completed quicker and with better results due to more efficient use of personnel ~-~-> Measure with time to mission completion and quality (?)
67 +**Note: **this claim spans the entire usecase. How do we deal with those types of claims? |all steps
68 +
44 44