Last modified by Tjalling Haije on 2025/09/15 09:25

From version 16.2
edited by Tjalling Haije
on 2025/07/14 11:34
Change comment: There is no comment for this version
To version 1.2
edited by Mark Neerincx
on 2025/07/07 10:02
Change comment: Added comment

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -UC01.1: Health and environmental monitoring (Firefighters)
1 +Usecase: Health sensors (Firefighters)
Parent
... ... @@ -1,1 +1,1 @@
1 -2\. Specification.b\. Use Cases.UC01\.0\: Health Sensors.WebHome
1 +2\. Specification.b\. Use Cases.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.TjallingHaije
1 +XWiki.MarkNeerincx
Content
... ... @@ -1,89 +1,44 @@
1 -=== **Health and environmental monitoring – Firefighting** ===
1 +=== **Health Sensor – Firefighting** ===
2 2  
3 -|=**Objective**|=(((
4 -[[OB03: Improve first responder health through monitoring of physical and mental state >>2\. Specification.Objectives.OB03\: Improve health through monitoring of physical and mental state .WebHome]]
5 -
6 -[[OB04: Improve safety by providing overviews and warnings of environment conditions>>2\. Specification.Objectives.OB04\: Improve safety by providing overviews and warnings of environment conditions.WebHome]]
7 -)))
3 +|=**Objective**|=Use health sensors to monitor firefighter vitals during operations, improving responder safety and enabling command decisions.
8 8  |**TDP**|TDP3, TDP6, TDP7
9 9  |**IDP**|IDP2, IDP4
10 10  |**Actors**|Firefighter, Squad Leader, Medic, Safety Officer
11 11  |**Pre-Condition**|Wearables are active and connected before firefighters enter the danger zone.
12 12  |**Post-Condition**|Health alerts handled; intervention performed if needed.
13 -|**Status**|Validated during and refined after CFT 1, CFT 2, CFT 3
14 14  
15 15  
16 16  
17 17  ----
18 18  
19 -(% style="margin: 15pt 0cm 7.5pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;" %)
20 -=== (% style="font-weight:normal" %)**Action Sequence**(%%) ===
14 +=== **Action Sequence** ===
21 21  
22 -(((
23 -
24 -)))
16 +1. **Equipment Check and Deployment**
17 + a. Firefighters receive wearable sensors at briefing.
18 + b. Devices are synced to central system and tested.
19 + c. Safety officer confirms connectivity before entry.
20 +1. **Live Monitoring in Action**
21 + a. Vitals (e.g. heart rate, CO exposure) are tracked during fire suppression.
22 + b. Firefighters receive vibration or LED warnings if thresholds exceeded.
23 + c. Alerts escalate automatically for predefined danger levels.
24 +1. **Remote Oversight and Alerts**
25 + a. Safety officer monitors dashboard for all team vitals.
26 + b. Critical alerts are sent to squad leader.
27 + c. Medic prepares for immediate support if triggered.
28 +1. **Intervention and Team Adjustment**
29 + a. Firefighter is pulled out if condition worsens.
30 + b. Medic assesses and logs health data.
31 + c. Squad leader adjusts team composition or rest timing.
32 +1. **Post-Incident Reporting**
33 + a. System logs are exported for incident review.
34 + b. Health data supports tactical evaluation and accountability.
25 25  
26 -=== ===
27 -
28 -(% start="1" style="list-style-type:decimal" type="1" %)
29 -1. (% lang="EN-US" style="font-size:10.5pt" %)**Equipment Check and Deployment**(%%)
30 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)a. Firefighters quickly put on wearable sensors when mission is confirmed(%%)
31 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)b. Safety officer confirms connectivity before entry.(%%)(((
32 -
33 -)))
34 -1. (% lang="EN-US" style="font-size:10.5pt" %)**Live Monitoring in Action**(%%)
35 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)a. Vitals (e.g. heart rate, CO exposure) are tracked during fire suppression.(%%)
36 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)b. Firefighters receive vibration or LED warnings if thresholds exceeded, but can turn these off when needed(%%)
37 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)c. Alerts escalate automatically for predefined danger levels.(%%)(((
38 -
39 -)))
40 -1. (% lang="EN-US" style="font-size:10.5pt" %)**Remote Oversight and Alerts**(%%)
41 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)a. Safety officer monitors dashboard for all team vitals with simple colour indicators(%%)
42 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)b. Critical alerts are sent to squad leader.(%%)
43 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)c. Local health services prepare for immediate support if triggered. In case of a false alarm squad lead is able to cancel it.(%%)(((
44 -
45 -)))
46 -1. (% lang="EN-US" style="font-size:10.5pt" %)**Intervention and Team Adjustment**(%%)
47 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)a. Firefighter is pulled out if condition worsens.(%%)
48 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)b. Medic assesses and logs health data.(%%)
49 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)c. Squad leader adjusts team composition or rest timing.(%%)(((
50 -
51 -)))
52 -1. (% lang="EN-US" style="font-size:10.5pt" %)**Post-Incident Reporting**(%%)
53 -(% style="font-size:10.5pt" %) (% lang="EN-US" %)a. System logs are exported for incident review.(%%)
54 -(% style="font-size:10.5pt" %) b. Health data supports tactical evaluation and accountability.(%%)(((
55 -
56 -)))
57 -
58 58  ----
59 59  
60 60  |=**Claims (title)**|=**Function**|=**Effect(s)**|=**Action Sequence Step(s)**
61 -|**CL1 Decreased physical workload for responders**|Health tracking, wearable alert|(((
62 -Reduces physical workload by alerting and preventing overexertion → Measure with ??
63 -)))|2a, 2b, 2c, 3a
64 -|(((
65 -**CL2 Improve safety for responders **
39 +|CL1 Heightened safety for responders|Health tracking, Alert escalation|Prevents unnoticed overexertion or gas exposure|2a, 2c, 3a
40 +|CL2 SA for own condition|Wearable alerts|Responders recognize and act on stress|2b
41 +|CL3 SA for command|Live dashboard, Auto-alerts|Command can intervene based on data|3a, 3b
42 +|CL4 Operational effectiveness|Medical input, Tactical decisions|Supports better crew deployment and rotation|4c, 5b
66 66  
67 -
68 -(gedrag (SA) > houden afstand van hazard (e.g. gas))
69 -)))|Monitoring and alerting of toxic gasses
70 -**Note**: is this an envisioned functionality?|(((
71 -Improves safety by reducing (toxic) gas exposure
72 -→ Measure with FR time near toxic gasses, or with near incident analysis.
73 -)))|2a, 2b, 2c, 3a
74 -|(((
75 -**CL4 Improve safety of responders for the commander**
76 -
77 77  
78 -)))|Safety officer monitors team vitals|(((
79 -Safety officer improves safety of FR by double checking FR status → measured as above
80 -)))|3a, 3b
81 -|**CL5 Decrease physical workload for responders**|Safety officer monitors team vitals|Safety officer decreases physical workload by double checking FR status → measured as above|
82 -|**CL6 Improved SA on personnel status for team lead (and command)**|Alert escalation, Live dashboard, Auto-alerts|Command has improved SA on health status of personnel
83 -→ Measure with NASA TLX ?|3a, 3b
84 -|**CL7 Support continuous learning with health data for after action review**|Health data over time of all FR is exported (and replayable?) after mission|Lessons learned can be idenitified and incorporated incorporated effectively
85 -→ measure with ?? |5a, 5b
86 -|**CL8 Task performance increased**|All of the other functions|Task is completed quicker and with better results due to more efficient use of personnel
87 -→ Measure with time to mission completion and quality?|all steps
88 -
89 -
XWiki.XWikiComments[1]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.MarkNeerincx
Comment
... ... @@ -1,1 +1,0 @@
1 -Note that we have to provide the measurement method for each effect that is mentioned. E.g. "supports better crew deployment and rotation" have te made more concrete. For a use case, we can specify the team composition and rotation schedule. Based on this, we can define a measurement
Date
... ... @@ -1,1 +1,0 @@
1 -2025-07-07 10:08:49.902